{"product_id":"tuohy-borst-adapter-threaded-flare-connector-7-fr-17-fr-0-091-inch-0-224-inch-2-3-mm-5-7-mm-0-2-inch-id-sideport-5-mm-11182","title":"Tuohy Borst Adapter, Threaded Flare Connector - 7 FR - 17 FR (0.091 inch - 0.224 inch, 2.3 mm - 5.7 mm); 0.2 inch ID Sideport (5 mm) - 11182","description":"\u003cdiv class=\"p-2 p-md-3\"\u003e\n\u003cdiv class=\"\" itemprop=\"description\"\u003e\n\t\t\t\t\tQosina offers a variety of valves and tuohy borst adapters that are in stock and ready for immediate delivery. Made with a red flat cap, Qosina part #11182 is a tuohy borst adapter with a clear polycarbonate body designed to prevent the backflow of fluid around instruments that are 7 FR - 17 FR. With a threaded flare connector and tubing sideport for flushing that accommodates 0.2 inch OD tubing, this large bore tuohy is ideal for applications which require the use of large instruments or devices. Qosina has a wide selection of large bore tuohy borst adapters to meet your project requirements.\n\t\t\t\t\u003c\/div\u003e\n\u003c\/div\u003e\u003ctable class=\"table table-sm\"\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eTechnical Detail\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\n7 FR - 17 FR (0.091 inch - 0.224 inch, 2.3 mm - 5.7 mm); 0.2 inch ID Sideport (5 mm)\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eMaterials\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nPC PC Colorant Silicone  \n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eCAD Model Available\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nYes\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eManufacturing Environment Classification\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nControlled but not formally classified\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eManufacturing Aids - Mold Release - Lubricant used\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nNo\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eColorant in Part\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nYes\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eRegrind Used to Manufacture This Part\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nNo\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eHazardous Goods\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nNo\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eProduct Shelf Life Non-Irradiation (months)\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nNo shelf life indicated by the supplier\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eAnimal Derived Ingredients (BSE\/TSE)\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nConforms with EMA\/410\/01 rev. 3\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eCalifornia Prop. 65\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nSOME Substances on the California Proposition 65 list have been knowingly or intentionally added\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eCalifornia Prop. 65 List Date\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\n1\/3\/2025 12:00:00 am\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eConflict Minerals\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nNot known to contain tantalum, tin, tungsten or gold.\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eEU MDR 10.4.1 (CMR\/ED)\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nNo Substance(s) Present Above Threshold\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eEU MDR 10.4.1 (CMR\/ED) Substance List\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nAnnex VI to CLP_ATP22 - 01 May 2026\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eEuropean Pharmacopoeia (EP) 3.1.X\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nInformation Not Available\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eHuman Derived Ingredients\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nDoes NOT intentionally contain human derived ingredients\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eLatex\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nDoes NOT intentionally contain natural latex\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eLatex in Packaging\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nDoes NOT intentionally contain natural latex\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eMedicinal Substances\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nDoes NOT intentionally contain medicinal substances\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eNanomaterials\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nDoes NOT intentionally contain nanomaterials\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003ePFAS\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nDoes NOT intentionally contain PFAS\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003ePFAS in Packaging\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nDoes NOT intentionally contain PFAS\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003ePyrogens\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nPyrogen free - Tested via USP \u0026lt;151\u0026gt;\/\u0026lt;161\u0026gt;\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eREACH SVHC\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nNo Substance(s) Present Above Threshold\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eREACH SVHC Candidate List\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\n2025 January 21 (247 Substances)\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eRoHS3 (2015\/863)\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nConforms to requirements of RoHS 2015\/863 (RoHS3)\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eEtO Compatible\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nYes\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eSteam Compatible\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nYes\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eBiocompatibility tested ISO 10993\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nYes\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eISO 10993-X Claim Based on\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nRaw Material\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eUSP Biocompatibility 87\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nRaw materials pass USP \u0026lt;87\u0026gt;\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eUSP Biocompatibility 88\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\npasses USP \u0026lt;88\u0026gt;, temperature not stated\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eUSP Biocompatibility Claim Based On\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nRaw Material\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eResidual Solvents: Tested via ICH Q3C Standard\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nNo ICH Q3C Testing Performed\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eElemental Impurities: Tested via ICH Q3D Standard\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nNo ICH Q3D Testing Performed\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eProtein Absorption Data Available\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nNo\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eExtractables Testing Claims\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nNo Extractables Testing Performed\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eVisible-Subvisible Particulate Claim\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nInformation Not Available\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eBioburden USP 61 62\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nNo bioburden information available\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eTested via USP  661.1\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nNo\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"row\" style=\"width: 35%;\"\u003eIntegrity Tested?\u003c\/td\u003e\n\u003ctd class=\"text-break\"\u003e\nNo\n\t\t\t\t\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"QSN","offers":[{"title":"Default Title","offer_id":47214767997105,"sku":"QS-11182","price":20.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/4498\/8081\/files\/11182_GRID.jpg?v=1776446618","url":"https:\/\/rpsmedcare.com\/products\/tuohy-borst-adapter-threaded-flare-connector-7-fr-17-fr-0-091-inch-0-224-inch-2-3-mm-5-7-mm-0-2-inch-id-sideport-5-mm-11182","provider":"RPS MedCare","version":"1.0","type":"link"}