AseptiQuik L Connector, Genderless, Barbed, High Temperature - Fits 3/4 inch ID Tubing (0.75 inch, 19.05 mm) - AQL17012HT
AseptiQuik L Connector, Genderless, Barbed, High Temperature - Fits 3/4 inch ID Tubing (0.75 inch, 19.05 mm) - AQL17012HT

AseptiQuik L Connector, Genderless, Barbed, High Temperature - Fits 3/4 inch ID Tubing (0.75 inch, 19.05 mm) - AQL17012HT

Technical Detail Fits 3/4 inch ID Tubing (0.75 inch, 19.05 mm) Materials PC PES PC...

Price :
Regular price $220.95
Regular price $220.95

QSN

QS-AQL17012HT

In Stock Sold Out 200

Notify Me

Technical Detail Fits 3/4 inch ID Tubing (0.75 inch, 19.05 mm)
Materials PC PES PC PTFE Silicone
CAD Model Available Yes
Manufacturing Environment Classification ISO Class 7 / 10,000 / Grade C
Colorant in Part Yes
Regrind Used to Manufacture This Part No
Hazardous Goods No
Product Shelf Life Non-Irradiation (months) 36
Product Shelf Life Post-Irradiation (months) 36
Animal Derived Ingredients (BSE/TSE) Animal Derived Component Free (ADCF)
California Prop. 65 SOME Substances on the California Proposition 65 list have been knowingly or intentionally added
California Prop. 65 List Date 1/9/2022 07:00:00 pm
Conflict Minerals Not known to contain tantalum, tin, tungsten or gold.
EU MDR 10.4.1 (CMR/ED) No Substance(s) Present Above Threshold
EU MDR 10.4.1 (CMR/ED) Substance List Annex VI to CLP_ATP17 - 17 December 2022
European Pharmacopoeia (EP) 3.1.X Information Not Available
Human Derived Ingredients Does NOT intentionally contain human derived ingredients
Latex Does NOT intentionally contain natural latex
Latex in Packaging Does NOT intentionally contain natural latex
Nanomaterials Does NOT intentionally contain nanomaterials
Pyrogens Pyrogen free - Tested via USP <85>
RoHS3 (2015/863) Conforms to requirements of RoHS 2015/863 (RoHS3)
Gamma Compatible Yes
Biocompatibility tested ISO 10993 Yes
ISO 10993-X Claim Based on Raw Material
USP Biocompatibility 87 Raw materials pass USP <87>
USP Biocompatibility 88 passes USP <88> 70C
USP Biocompatibility Claim Based On Raw Material
Residual Solvents: Tested via ICH Q3C Standard Contains ICH Q3C Class 1 or 2 Residual Solvents
Elemental Impurities: Tested via ICH Q3D Standard Contains ICH Q3D Class 1, 2, 2B or 3 Elemental Impurities
Protein Absorption Data Available No
Extractables Testing Claims Other Report
Visible-Subvisible Particulate Claim USP <788>
Tested via USP 661.1 Yes
Integrity Tested? Yes, routine random samples are tested