PharmaTainer™ Bottle, Non-Sterile, 5/Vacuum-Sealed Pack - 2 Liter; 48 mm cap - 12708
Pharmatainer™ bottles are available in sizes ranging from 125 mL to 2 liters, made in...
Price :
Regular price
$170.95
Regular price
$170.95
Pharmatainer™ bottles are available in sizes ranging from 125 mL to 2 liters, made in PET (COPE). They are injection blow molded and capped in an ISO 5 cleanroom environment and then packaged in an ISO 7 cleanroom with inner layer vacuum sealed packaging. As per the manufacturer, they are designed for biomanufacturing liquid transfer, storage and transport. Pharmatainer™ caps (part numbers 12716–12719) are also available and feature barbed port configurations for use with these bottles.
| Technical Detail | 2 Liter; 48 mm cap |
| Materials | COPE HDPE |
| CAD Model Available | No |
| Manufacturing Environment Classification | ISO Class 7 / 10,000 / Grade C |
| Manufacturing Aids - Mold Release - Lubricant used | No |
| Colorant in Part | No |
| Regrind Used to Manufacture This Part | No |
| Hazardous Goods | No |
| Product Shelf Life Non-Irradiation (months) | 84 |
| Animal Derived Ingredients (BSE/TSE) | Animal Derived Component Free (ADCF) |
| California Prop. 65 | Information Not Available |
| Conflict Minerals | Not known to contain tantalum, tin, tungsten or gold. |
| European Pharmacopoeia (EP) 3.1.X | Information Not Available |
| Human Derived Ingredients | Does NOT intentionally contain human derived ingredients |
| Latex | Does NOT intentionally contain natural latex |
| Latex in Packaging | Does NOT intentionally contain natural latex |
| Medicinal Substances | Does NOT intentionally contain medicinal substances |
| Nanomaterials | Does NOT intentionally contain nanomaterials |
| Pyrogens | Not tested for pyrogens |
| REACH SVHC | No Substance(s) Present Above Threshold |
| RoHS3 (2015/863) | Conforms to requirements of RoHS 2015/863 (RoHS3) |
| Gamma Compatible | Yes |
| X-Ray Compatible | Yes |
| Biocompatibility tested ISO 10993 | Yes |
| ISO 10993-X Claim Based on | Raw Material |
| USP Biocompatibility 87 | Finished component passes USP<87> |
| USP Biocompatibility 88 | Passes USP <88>, temperature not stated |
| USP Biocompatibility Claim Based On | Finished Component |
| Residual Solvents: Tested via ICH Q3C Standard | No ICH Q3C Testing Performed |
| Elemental Impurities: Tested via ICH Q3D Standard | Contains NO ICH Q3D Class 1, 2, 2B or 3 Elemental Impurities |
| Protein Absorption Data Available | No |
| Extractables Testing Claims | Suitable for intended use according to USP <665> |
| Visible-Subvisible Particulate Claim | USP <788> |
| Bioburden USP 61 62 | Bioburden values available |
| Tested via USP 661.1 | No |
| Integrity Tested? | Yes, 100% |