Sani-Tech STHT-R-HD Tubing - 65A Durometer; 2 inch ID x 2.695 inch OD (2 inch x 2.695 inch, 50.8 mm x 68.45 mm) x 25 ft coil (7.62 m) - T2533
Sani-Tech STHT-R-HD Tubing - 65A Durometer; 2 inch ID x 2.695 inch OD (2 inch x 2.695 inch, 50.8 mm x 68.45 mm) x 25 ft coil (7.62 m) - T2533

Sani-Tech STHT-R-HD Tubing - 65A Durometer; 2 inch ID x 2.695 inch OD (2 inch x 2.695 inch, 50.8 mm x 68.45 mm) x 25 ft coil (7.62 m) - T2533

Sani-Tech STHT-R-HD is a heavy duty braid-reinforced silicone tubing for high pressure environments where strength...

Price :
Regular price $3,429.95
Regular price $3,429.95

QSN

QS-T2533

In Stock Sold Out 200

Notify Me

Sani-Tech STHT-R-HD is a heavy duty braid-reinforced silicone tubing for high pressure environments where strength and durability are critical.
Technical Detail 65A Durometer; 2 inch ID x 2.695 inch OD (2 inch x 2.695 inch, 50.8 mm x 68.45 mm) x 25 ft coil (7.62 m)
Materials Silicone
CAD Model Available No
Packaging 25 ft coil (7.62 m)
Manufacturing Environment Classification ISO Class 7 / 10,000 / Grade C
Manufacturing Aids - Mold Release - Lubricant used No
Colorant in Part No
Regrind Used to Manufacture This Part No
Hazardous Goods No
Product Shelf Life Non-Irradiation (months) 60
Animal Derived Ingredients (BSE/TSE) Conforms with EMA/410/01 rev. 3
California Prop. 65 Information Not Available
Conflict Minerals Not known to contain tantalum, tin, tungsten or gold.
EU MDR 10.4.1 (CMR/ED) No Substance(s) Present Above Threshold
European Pharmacopoeia (EP) 3.1.X Pass 3.1.9 Silicone
Human Derived Ingredients Information Not Available
Latex Does NOT intentionally contain natural latex
Latex in Packaging Does NOT intentionally contain natural latex
Medicinal Substances Information Not Available
Nanomaterials Does NOT intentionally contain nanomaterials
Pyrogens Pyrogen free - Tested via USP <151>/<161>
RoHS3 (2015/863) Conforms to requirements of RoHS 2015/863 (RoHS3)
EtO Compatible Yes
Gamma Compatible Yes
Biocompatibility tested ISO 10993 Yes
ISO 10993-X Claim Based on Raw Material
USP Biocompatibility 87 Raw materials pass USP <87>
USP Biocompatibility 88 Passes USP <88>, temperature not stated
USP Biocompatibility Claim Based On Raw Material
Protein Absorption Data Available No
Extractables Testing Claims Modified BPOG
Visible-Subvisible Particulate Claim USP <788>
Bioburden USP 61 62 No bioburden information available