T Connector, Reducer, Barbed, Natural - Fits 1/2 inch ID (0.5 inch, 12.7 mm); 3/8 inch ID Tubing (0.375 inch, 9.53 mm) - 61123
Technical Detail Fits 1/2 inch ID (0.5 inch, 12.7 mm); 3/8 inch ID Tubing (0.375...
Price :
Regular price
$4.95
Regular price
$4.95
| Technical Detail | Fits 1/2 inch ID (0.5 inch, 12.7 mm); 3/8 inch ID Tubing (0.375 inch, 9.53 mm) |
| Materials | PP |
| CAD Model Available | Yes |
| Manufacturing Environment Classification | ISO Class 7 / 10,000 / Grade C |
| Manufacturing Aids - Mold Release - Lubricant used | No |
| Colorant in Part | No |
| Regrind Used to Manufacture This Part | No |
| Hazardous Goods | No |
| Product Shelf Life Non-Irradiation (months) | 120 |
| Animal Derived Ingredients (BSE/TSE) | Animal Derived Component Free (ADCF) |
| California Prop. 65 | NO Substances on the California Proposition 65 list have been knowingly or intentionally added |
| California Prop. 65 List Date | 12/29/2023 12:00:00 am |
| Conflict Minerals | Not known to contain tantalum, tin, tungsten or gold. |
| EU MDR 10.4.1 (CMR/ED) | No Substance(s) Present Above Threshold |
| EU MDR 10.4.1 (CMR/ED) Substance List | Annex VI to CLP_ATP20 - 01 February 2025 |
| European Pharmacopoeia (EP) 3.1.X | Information Not Available |
| Human Derived Ingredients | Does NOT intentionally contain human derived ingredients |
| Latex | Does NOT intentionally contain natural latex |
| Latex in Packaging | Does NOT intentionally contain natural latex |
| Medicinal Substances | Information Not Available |
| Nanomaterials | Information Not Available |
| PFAS | Does NOT intentionally contain PFAS |
| Pyrogens | Not Tested for Pyrogens |
| REACH SVHC | No Substance(s) Present Above Threshold |
| REACH SVHC Candidate List | 2026 February 04 (253 Substances) |
| RoHS3 (2015/863) | Conforms to requirements of RoHS 2015/863 (RoHS3) |
| EtO Compatible | Yes |
| Gamma Compatible | Yes |
| Biocompatibility tested ISO 10993 | Yes |
| ISO 10993-X Claim Based on | Raw Material |
| USP Biocompatibility 87 | Information Not Available |
| USP Biocompatibility 88 | passes USP <88> 121C |
| USP Biocompatibility Claim Based On | Raw Material |
| Residual Solvents: Tested via ICH Q3C Standard | No ICH Q3C Testing Performed |
| Elemental Impurities: Tested via ICH Q3D Standard | No ICH Q3D Testing Performed |
| Protein Absorption Data Available | No |
| Extractables Testing Claims | No Extractables Testing Performed |
| Visible-Subvisible Particulate Claim | Information Not Available |
| Bioburden USP 61 62 | No bioburden information available |
| Tested via USP 661.1 | No |
| Integrity Tested? | No |